Interior and Electrical
QA Junior was not happy about the esthetics and long term durability of exposed Tyvek on the inside. My original thinking was that it had its advantages - light walls help with visibility and more importantly the exposed studs provide a built-in rack system for storing tools. Junior QA pointed out that 1/4" plywood doesn't cost that much (per sheet anyway) and I promised I'd look into it.
Using it for the shed interior is the perfect application for this salvage wood as it is insubstantial, uneven and rarely straight. Since I wanted to keep the studs exposed, that meant putting the boards between the studs, and the studs are straight, so we got a conflict there. I could start with the widest and longest boards:
I cleared out my table saw in the barn so I could rip the boards to get them to be a good fit, and in the process cut the bow off of them so they'd be straighter.
After completing all the way around we clearly have a paneled look. I'm very pleased with the way that looks!
I was thinking the peak could stay white but QA (senior) said that would look unfinished and she was right that it didn't take long to fill it in. I've used the same board to do each side working out from the middle, hoping to some mirror symmetry action.
With the paneling done, it was time to work on the electrical. The barn you've seen in pictures from prior posts has power, and I had more than 100' of UF-B (Underground Feeder) 12 gauge cable leftover from the well-house project, so I thought "why not run power to the shed?" I kinda found out why not - because its a ****load of work! But always good to re-justify having that backhoe tractor attachment, eh?
- cross the branch (creek) which it could do by going over the driveway culvert (which is quite deep),
- go under the fiber optic cable running up the driveway and
- go under the garden spring drain pipe.
And 53" from the edge of the road (which is a fixed edge at this spot since its where the culvert is).
As you can see above I installed a short length of conduit to run the UF-B cable through under the fiber. If/when the fiber needs to be replaced hopefully all this will keep it from getting tangled with the electrical. There really should be at least a one foot vertical gap between them but that's just more than I'm willing to do. Here is ditch with wire ready for burial:
One thing I've learned about construction is that its always a good idea to document where you put things that are going to get covered up. So took around 50 pictures of which you are getting a sample. In addition to pictures (which are rather ephemeral and may not be on hand when needed), for buried lines its always good to mark them with tape in the ground above both as a warning to future diggers but also as confirmation that you are digging in the right spot if you are looking for what's under there. I first saw this being done by French Broad Electric when they put in the underground line to our house and it made a lot of sense.
Of course I couldn't find any of the 2 inch wide yellow "WARNING" tape that is meant for this purpose although I thought I remembered buying some. So the multi-colored garden marking plastic tape would have to do, set just an inch or two above the wire:
And then put another round of tape a couple of inches below the surface:
PS. two weeks later I came across my roll of 2" wide yellow caution tape on a bookshelf in the house!
The electrical terminus in the shed:
In a shed project the rough-in step and finish electrical work steps done together. Since I had a couple lengths of electric conduit left in from the house project (sitting in the barn for last 12 years) I deciding to use them here to keep the Romex wire from being hit and potentially damaged by garden tools.
However once to the "ceiling" I thought it OK to just run the bare Romex.
The original idea was to use the electrical outlet box as the junction box for the lights, but when I found that I had five pairs of wires that needed to be managed, I changed plans to have a separate outlet box and dedicate the first box to be used as a junction box which now had six pairs coming into it:
And with some wire wrangling I managed to clean it up pretty well:
The last step was installing the light fixtures. I happened to go by the Madison Community Housing Coalition ReClaim hardware store (our version of the Habitat for Humanity Restore) and noticed a pair of used fixtures that I liked. (QA finds them a bit of the chintzy side). The fixture and the tools you need:
Over the course of running the Romex to the south light my standards went up for how its done. So I removed the original "ceiling" run of Romex shown five pictures above and drilled thru the rafters so it could run on top of the plate and be better hidden:
End result with a 100W incandescent bulb:
Very cozy in the evening light:
Bonus nature photo: In the construction area I spotted one of the weirdest looking bugs I've ever seen. The body is about an inch long. A look that sends a "don't even think about it" message.